Nighthawk Kn-cop-dp User Manual

Ac powered, plug-in carbon monoxide alarm, Consumer benefits, Features and benefits

Advertising

AC Powered, Plug-In
Carbon Monoxide Alarm

Kidde KN-COPP-3 (900-0076) (21005294) AC Powered, Plug-In Carbon Monoxide Alarm Kidde 21006973 (6pcs bulk) AC Powered, Plug-In Carbon Monoxide Alarm Kidde KN-COP-DP-10YB (900-0282) Worry-Free Bedroom Plug-in Carbon Monoxide Alarm with Sealed Lithium. Nighthawk Carbon Monoxide Alarm AC Powered, Plug-In with Battery Backup and Digital Display. Part Number 900-0234. Model KN-COP-DP-LS. The Nighthawk 900-0234 AC Powered, Plug-In carbon monoxide alarm with battery backup and digital display is an easy to install unit that provides reliable protection against the dangers of carbon monoxide. Plug-In Carbon Monoxide Alarm — AC Powered with Sealed Lithium Battery Backup, Digital Display and Voice Alarm Part Number: 900-0282 Model KN-COP-DP-10YB Architectural and Engineering Specifications Technical Specifications The carbon monoxide alarm shall be Kidde model number KN-COPDP-10YB (Part Number 900-0282) or approved equal. The carbon monoxide alarm shall be Kidde Unit Number KN-COP-DP (part number 900-0056) or approved equal. It shall be powered by a 120VAC, 60 Hz source. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operation range shall be 5% - 95% relative humidity.

• Part Number 900-0056 • KN-COP-DP

Manual CARBON MONOXIDE Detector KN-COB-ICB, P/N 900-0167 Kidde Carbon Monoxide Alarm User's Manual Kidde Carbon Monoxide Alarm User's Manual Kidde Carbon Monoxide Alarm User's Guide Model KN-COB-DP-H Kidde Carbon Monoxide Alarm User Manual Kidde Carbon Monoxide Alarm User Manual Kidde Carbon Monoxide Alarms Specification Sheet Kidde Carbon. A carbon monoxide detector can save your life, but only if it's functioning properly. If you suspect your Kidde Nighthawk carbon monoxide alarm system isn't functioning as it should, run a quick series general troubleshooting diagnostics to check the device.

Description

The Kidde 900-0056 is an AC powered, plug-in carbon
monoxide alarm that can be installed easily in any stan-
dard wall outlet. The 900-0056 uses advanced technolo-
gy to monitor for carbon monoxide levels in your home
and features a Nighthawk

TM

, electrochemical sensor,

the world’s most accurate carbon monoxide sensing
technology*. The digital display feature allows for easy
viewing of carbon monoxide levels.

Consumer Benefits

The Kidde 900-0056 AC powered, plug-in carbon
monoxide alarm provides you and your family a warning
signal against the dangers of carbon monoxide levels in
your home. This alarm is easily installed in any of your
AC wall outlets. The digital display feature allows for
easy viewing of carbon monoxide levels from 30-999PPM
(parts per million). The 900-0056 is UL listed and offers a
5-year limited warranty.

Features and Benefits

• Digital Display – Displays the level of carbon monoxide

the unit is sensing. The unit updates this reading every
15 seconds.

• Peak Level Button – Displays the peak CO level

recorded by the alarm since it was last reset or unplugged.

• Test Button – Tests unit’s electronic circuitry and horn

and resets the unit during alarm.

*Based on accuracy claims of major manufacturers

NIGHTHAWK

TECHNOLOGY

World’s Most Accurate

Carbon Monoxide Alarm*

TM

Digital Display

Displays the level of carbon monoxide the unit is sensing.
The unit updates this reading every 15 seconds.

Test/Reset Button

Tests units electronic circuitry and horn and resets
the unit during alarm.

Peak Level Button

Displays the peak CO level recorded by the alarm since
it was last reset or unplugged.

Alerts user to replace CO alarm
after 7 years of operation

NEW

FEATURE:

Advertising
Popular Brands
Popular manuals

AC Powered, Plug-In

Carbon Monoxide Alarm

• Part Number 900-0056 • KN-COP-DP

Digital Display

Displays the level of carbon monoxide the unit is sensing.

The unit updates this reading every 15 seconds.

Test/Reset Button

Tests units electronic circuitry and horn and resets the unit during alarm.

Peak Level Button

Displays the peak CO level recorded by the alarm since it was last reset or unplugged.

Nighthawk User Manual

NEW Alerts user to replace CO alarm

FEATURE: after 7 years of operation

NIGHTHAWKTM

TECHNOLOGY

Most Accurate Carbon Monoxide Alarm*

Description

The Kidde 900-0056 is an AC powered, plug-in carbon monoxide alarm that can be installed easily in any standard wall outlet. The 900-0056 uses advanced technology to monitor for carbon monoxide levels in your home and features a NighthawkTM, electrochemical sensor,

the world’s most accurate carbon monoxide sensing technology*. The digital display feature allows for easy viewing of carbon monoxide levels.

Consumer Benefits

The Kidde 900-0056 AC powered, plug-in carbon monoxide alarm provides you and your family a warning signal against the dangers of carbon monoxide levels in your home. This alarm is easily installed in any of your AC wall outlets. The digital display feature allows for easy viewing of carbon monoxide levels from 30-999PPM (parts per million). The 900-0056 is UL listed and offers a 5-year limited warranty.

Features and Benefits

Digital Display – Displays the level of carbon monoxide the unit is sensing. The unit updates this reading every 15 seconds.

• Peak Level Displays the peak CO level

recorded by the alarm since it was last reset or unplugged.

Test Button – unit’s electronic circuitry and horn and resets the unit during alarm.

Nighthawk Co Detector Manual

AC Powered, Plug-In

Carbon Monoxide Alarm

User

Architectural and Engineering

Specifications

The carbon monoxide alarm shall be Kidde Unit Number KN-COP- DP (part number 900-0056) or approved equal. It shall be powered by a 120VAC, 60 Hz source. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operation range shall be 5% - 95% relative humidity.

The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL 2034 Single Station Carbon Monoxide Detectors. The unit shall provide accuracy of +/-20% + 15 parts per million (ppm) when reading CO concentration levels.

The alarm shall include an attached plug that can be installed in any outlet following the UL/NFPA/Manufacturer’s recommended guidelines. The plug shall be capable of being rotated so the alarm remains vertical independent of whether the electrical socket is mounted vertically or horizontally.

The unit shall incorporate a digital display that meets the sensitivity requirements of UL 2034. The display will identify the levels of CO in parts per million (ppm) once that level reaches 30ppm (i.e.:

“abnormal” levels). The display will have a red dot in the lower right corner that will blink to indicate the normal operation.

The alarm shall include a test button that will electronically simulate the presence of CO and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation.

The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding level of CO.

Nighthawk Kn-cop-dp Manual

The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. When the unit detects carbon monoxide, the alarm pattern will be four (4) short beeps – followed by five (5) seconds of silence – followed by four (4) short beeps. A number reading will appear on the digital display identifying the CO concentration (in ppm).

*Based on accuracy claims of major manufacturers

Part Number 900-0056

Unit Number KN-COP-DP

The unit shall include a peak level memory feature that will store the peak CO level sensed since the unit was last reset. The peak CO level stored in the unit’s memory shall be displayed (in ppm) on the digital display by pressing the appropriate button on the unit. The memory shall also be capable of being reset.

The unit shall be listed to UL 2034. It shall also include a 5-year manufacturer’s limited warranty.

Technical Specifications

Part Number:

900-0056

Unit Number:

KN-COP-DP

UPC Number:

7-84608-00560-1

Power Source:

120VAC

Sensor:

Electrochemical

Audio Alarm:

85dB at 10ft

Temperature Range:

40˚F (4.4˚C) to 100˚F (37.8˚C)

Humidity Range:

Up to 95% relative humidity (RH)

Size:

Casio fx 260 calculator user manual. 5.65”L x 3.25”W x 1.9”H

Weight:

1lb

Interconnects:

No

Wiring:

Plug-In

LED:

Displays CO concentration in PPM

Warranty:

5 year limited

3.25'

1.9'

5.65'

Ordering Information

Clam Shell UPC: 7-84908-00560-1

Part

Dimensions

Case/

Layers/

Skid

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

Skid

Weight

900-0056**

N/A

Individual

7 x 2.5 x 10.75

1lb

N/A

N/A

N/A

900-0056-02

107 84908 00560 8

PDQ (2 units)

7.75 x 6 x 11.75

2lbs

105

3

210lbs

900-0056-07

207 84908 00560 5

Master Pack (4 units)

7.75 x 11.5 x 12

4lbs

80

4

320lbs

900-0056-012

307 84908 00560 2

Cut Case (12 units)

15 x 18 x 12

12lbs

18

3

216lbs

900-0056-036

407 84908 00560 9

Power Tower (36 units)

20 x 24 x 50 (incl. pallet)

36lbs

3

3

108lbs

**Not for sale by individual unit

1

2

4

12

36

UNIT

PDQ

MASTER PACK

CUT CASE

POWER TOWER

Distributed by:

1394 South Third Street, Mebane NC 27302

1-800-880-6788 • www.kiddeus.com

Nighthawk Kn-cob-dp User's Guide

To continue the download you need to go through the captcha:

Att Nighthawk User Manual